This setting lets you enable the critical output of the fleet controller when a critical event happens. These events are:
- An unexpected answer on critical question during checklist.
- Excessive idling, vehicle is not moving for a set period and no one is on the seat.
- Critical impact or collision of any sort that met or exceeded the critical set value in Gs.
- From the menu on the ribbon bar, click ADMINISTRATION and then Critical Output.
- Locate the category to edit and click
. - Tick the checkbox on "Enable Critical Ouput" to enable, read and understand RCT's safety notice, tick the checkbox at the end and take necessary safety precautions.
- Tick off "Enable Critical Ouput" to disable critical output, remaining settings are dimmed and cannot be set, proceed to step 8.
- Select "Output Delay" setting from dropdown list with pre-set of 5, 10, 60, 120, 180 or 240 seconds. This is the delay time before the critical output turns ON. A countdown timer will be shown on the fleet controller's display.
- Select "Buzzer Duration" setting from dropdown list with pre-set of 1, 2, 3, 5, 10, 15 or 25 seconds. This is the duration of the audible buzzer on the fleet controller's display when critical event occur.
- Select "Output Period" setting from dropdown list with pre-set values below. This is how long the critical output will be engaged and get turned off.
- 5 sec or IGN OFF
- 10 sec or IGN OFF
- 60 sec or IGN OFF
- 10min or RESET by Supervisor
- 1 hr or RESET by Supervisor
- 4 hr or RESET by Supervisor
- 8 hr or RESET by Supervisor
- Until reset by Supervisor
- Click
.
Notes on Operation
- The Critical Output will turn on without delay when a critical checklist question is failed.
- The buzzer will always sound for 15 seconds just before the Critical Output turns on.